D4120 Duct Smoke Detector Wiring Diagram

This detection method when combined.
D4120 duct smoke detector wiring diagram. System sensor smoke detector wiring diagram system sensor convention 4 wire duct smoke detector d4120 wiring fancy. Model d4120 and d4s duct smoke detectors utilize 4 wire photoelectric technology for the detection of smoke. It shows the components of the circuit as streamlined shapes as well as the power as well as signal links between the gadgets. D4120 duct smoke detector the innovairflex series are the only duct smoke detectors flexible enough to fit configurations from square to rectangular and everything in between.
The innovairflex housing provides ample wiring space a the air duct smoke detector shall be a system sensor innovairflex d photoelectric duct. Addressable duct smoke detector wiring diagram d4120 duct smoke detector wiring diagram duct smoke detector installation manual duct smoke detector wiring diagram hvac smoke detector wiring diagram siemens duct smoke detector wiring diagram siga sd duct smoke detector wiring diagram simplex duct smoke detector wiring diagram sl. Smoke introduced into an air duct system will be distributed throughout the entire building. 3 indicated connections needed to be made in the field by quali fied electrician.
Features 4 wire photoelectric integrated low flow technology air velocity rating from 100 ft min to 4 000 ft min 0 5 m s to 20 32 m sec. Model d4120 and d4s duct smoke detectors utilize 4 wire photoelectric tech nology for the detection of smoke. A wiring diagram is a simplified traditional pictorial depiction of an electric circuit. How to wire smoke detectors in series diagram new duct at detector wiring system sensor convention 4 wire duct smoke detector d wiring with.
Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. 2 these wiring diagrams apply to model d4120 duct smoke detector made by system sensor with either photoelectric detector head. Efl and 24 vac supply efl and 120 vac supply. This detection method when com bined with an efficient housing samples air passing through the duct al.
For reference we are going to be covering the connections on the system sensor d4120 model duct detector as this is the most common version used by mechanical contractors. Smoke introduced into an air duct system will be distributed throughout the entire building. Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. Also note that the system sensor d4120 is the replacement for the dh100acdclp the reason to mentioned this is the fact that system sensor was smart when creating the newer d4120 by carrying over the same terminal numbers.
This detection method when combined.